AccuStar
?/DIV>
Electronic Clinometer
AccuStar Rev. 3
www.meas-spec.com
2012-august
3/7
RATIOMETRIC OUTPUT MODEL
The Ratiometric clinometer is a signal
conditioned sensor that has been designed to
operate like a potentiometer. This is a three wire
device: power; power ground; and signal. The
signal is referenced to power ground. A
regulated power supply is required since the
output is supply dependent. The midscale
output, zero degrees, is 1/2 the supply voltage
while the scale factor is also supply dependent.
With its low power consumption, 0.5 mA, this
device is ideal for battery supplied applications.
The Ratiometric clinometer was designed with
EMI and ESD suppression circuitry on every
line.
ELE TRI AL PE IFI ATI N
Input voltage
nominal
+9VDC
In ut volta e ran e
+5 to +15VDC
In ut current
0.5mA
Scale factor
+9VDC in ut
30mV / degree, ?0%
L
r i n min
1 k&
Level out ut 0
o
?Vcc
ELE TRI AL
NNE TI N
Red
+ 5 to +15VDC re ulated
Black
Power round
Yellow
Signal output
referenced to ower round